logo
Invia messaggio
Casa
Prodotti
Video
Circa noi
Giro della fabbrica
Controllo di qualità
Contattici
Richiedere un preventivo
Notizie
Notizie della società
BOGEN PUMPS
Casa ProdottiPompa di trasferimento del diaframma

Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration

La Cina BOGEN PUMPS Certificazioni
La Cina BOGEN PUMPS Certificazioni
BA50 È BUONO PER ORA

—— Pozzo del lavoro

Buon lavoro, grazie per darmi una grande vacanza. Auguri, Vinod

—— Vinod Bernardo

Cooperazione piacevole! Abbiamo apprezzato per il supporto gentile della vostra società sui nostri progetti. Servizio molto buon

—— Sig. Hussain

Sono ora online in chat

Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration

 Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration
 Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration

Grande immagine :  Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration

Dettagli:
Luogo di origine: La Cina
Marca: BSK
Numero di modello: BSKA25AL-P99-A
Termini di pagamento e spedizione:
Quantità di ordine minimo: 10 unità
Prezzo: negotiable
Imballaggi particolari: Legno
Tempi di consegna: 5 GIORNI
Termini di pagamento: CATENA DELL'OROLOGIO T/T
Capacità di alimentazione: 1000 unità al mese
Garanzia:: Un anno
Descrizione di prodotto dettagliata
Nome del prodotto: pompa a diaframma pneumatica Materiale: Acciaio fuso
Pressione d'aria massima: 8.3bar rumore: <80db>
Max. Installation Dimension: 249.5×360.5×245mm Flusso massimo: 135L/MIN
Evidenziare:

food grade diaphragm pump

,

air operated submersible pump

Positive Displacement Water Pump Air Operated With Low Vibration

 

 

Air diaphragm pump(also know as a Membrane pump, air operated double diaphragm pump(AOOD) or pneumatic diaphragm pump)that uses a combination of the reciprocating action of a rubber,thermoplastic or diaphragm and suitable valves either side of the diaphragm (check valve,butterfly valves,flap valves,or any other form of shut-off valves) to pump a fluid.

 

Product Description:

 

Air Inlet

1/4-18NPTF-1

Fluid Outlet

1-11-1/2NPTF-1,Rp1-11BSP

Fluid Inlet

1-11-1/2NPTF-1,Rp1-11BSP

Max. Flow

135L/Min

Max. Head

70M

Max. Self-priming Lift (dry)

4m

Max. Air Pressure

8.3bar

Max. Particle Diameter

3mm

Max. Installation Dimension

249.5×360.5×245mm

Weight

9.5kg

Noise

<80db

 

 

Specifications

 

Air Diaphragm Pump
1. Non leakage
2. Good self priming performance
3. Convey all kinds of medium
4. Material:Cast steel,Alu,SS,PP

 

Pneumatic Diaphragm Pump Advantages:

1. Explosion-proof, zero leak, simple operation.

2. Idling capability,Self suction, No complex control.

3. Diversity of material,no rotating parts,applicable to various erosive situations.

4. Diaphragm, ball and ball seat adopt imported materials with longer service life.

5. Modularization of main valve and air motor. No broken, easy to disassemble and repair.

 

Pay attention to the following points when operating with a pneumatic diaphragm pump:


1. Ensure that the maximum particles contained in the fluid do not exceed the maximum safety of the pump through the particle diameter standard.
2. The intake pressure should not exceed the maximum allowable pressure of the pump. Compressed air above the rated pressure may cause personal injury and property damage and damage the performance of the pump.
3. Ensure that the pumping piping system can withstand the highest output pressure achieved, and ensure the clean and normal working conditions of the driving pneumatic system.
4. Static sparks may cause explosions and personal injury and property damage. Use wires with a large cross-sectional area as needed to properly ground the grounding screws on the pump.
5. The grounding requirements are in compliance with local laws and regulations and some special requirements on site.
6. Tighten the pump and each connecting pipe joint to prevent static sparks from being generated by vibration. Use an antistatic hose.
7. Periodically check and test the reliability of the grounding system, requiring a grounding resistance of less than 100 ohms.
8. Maintain good exhaust and ventilation, away from inflammable, explosive and heat sources.

Maximum Applied Temperature Limits (diaphragm / ball / seal material)  

 

 

Acetal ···············································40°-         150°F        (4.4- 65.5°C)  

Santoprene····················································-40°- 225°F (-40°- 107.2°C)   ·····································································40°- 220°F (4.4°- 104°C)   Nitrile·······································································10°- 180°F (-12°- 82°C)   Viton······························································-40°- 350°F (-40°-176.6°C)   Hytrel·········································································-20°-150°F (-12°- 93°C)   Kynar·····································································10°-200°F (-28.9°- 65.5°C)   Polypropylene····················································32°- 175°F (0-79.4°C)

 

 

1”  Flow diagram

 

 Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration 0

 

Installation dimensions:

 

 Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration 1

 

 Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration 2

 

 

 Diaphragm Transfer Pump Positive Displacement Diaphragm Pump With Low Vibration 3

 

 

 

 


 

 

Dettagli di contatto
BOGEN PUMPS

Persona di contatto: Mr. ALLSON

Telefono: 008618122100289

Invia la tua richiesta direttamente a noi (0 / 3000)